Anesthesia Machine Main Body Introduction |
Anesthesia modes: |
closed, semi-closed, semi-open |
Usage |
Imported high-precision proportional valve control tidal volume, suitable for |
adults and children |
Ventilation mode |
IPPV,SIPPV,IMV, SIMV,MANUAL |
Optional |
Anesthesia machine monitor |
Respiratory mechanics |
pressure - time waveform, |
waveform display |
flow rate - time waveform, |
Real-time monitoring and alarm |
tidal volume, minute ventilation, oxygen concentration, airway pressure, |
Power outages, breathe |
Display |
HD 5.4'' LCD display, a variety of information display function |
such as pressure,flow, flow waveform and lung function ring |
Breathing circuit |
Integrated modular design, safety, low air resistance, can be pasteurized, with |
internal overpressure release valve, the international advanced cuptype sodalite |
jar, hand disassembly |
Evaporator |
Ensure accurate and stable concentration output, with interlock devices, |
have the effect to prevent misuse |
PEEP |
high-performance electronic PEEP control valve |
Optional |
high-end monitor products, imported plus end-tidal and depth of anesthesia |
monitoring |
Gas source |
oxygen (O2), nitrous oxide (N2O), air |
rated working pressure |
(0.35 ~ 0.45) MPa |
Parameter Datas |
Flow meter(Four tubes type) |
The adjustment range of the capillary tube of O2,N2O:0.1~1L/min, |
The adjustment range for crude tube of O2,N2O:1.2~10L/min |
The adjustment range for air flow meter: 0.1~10L/min |
Using oxygen, nitrous oxide proportional control device to ensure that the |
oxygen concentration should not be less than 25% |
Evaporator |
Concentration flow adjustment range: |
Enflurane 0 ~ 5% (V / V), isoflurane 0 ~ 4% (V / V) |
Fast oxygen range |
(35 ~ 75) L / min |
Oxygen protection |
When insufficient oxygen, nitrous oxide automatic shutoff device |
larm duration: 7s, the alarm sound is not less than 57dB (A) |
Tidal volume (Vet) setting range |
(0~1500)mL |
breathing frequency (f) setting range |
(2 to 99) times / min |
I / E ratio setting range |
4: 1 to 1: 10 |
Pinsp setting range |
(0.5 ~ 5) kPa (5 ~ 50cmH2O) |
PEEP adjustment range |
(0.5 ~ 2) kPa (5 ~ 20cmH2O), or turned off. |
Ptr setting range |
(- 0.1 ~ -0.9) kPa (-1 ~ -9cmH2O), or turned off |
TP setting range |
5% ~ 60% of the inspiratory phase, can also be turned off |
|
Normal working conditions |
Ambient temperature |
(10 ~ 30) ºC |
Relative humidity |
≤80% |
atmospheric pressure |
(86 ~ 106) kPa |
Power Supply |
AC (220 ± 22) V, (50 ± 1) Hz |