Customization: | Available |
---|---|
Classification: | ICU Equipment |
Type: | Patient Monitor |
Still deciding? Get samples of US$ 240/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TECHNICAL SPECIFICATIONS
Quality Standards and Classification
CE, ISO13485
SFDA: Class b
Anti-electroshock degree:
Classequipment
(internal power supply)
TEMP/SpO 2 /NIBP: BF
ECG/Resp: CF
Application Range
Adult/Pediatric/Neonatal/Medicine/Surgery/
Operating Room/ICU/CCU
Display
8"real color LED screen
Environment
Operating environment :
Temperature: 0 ~ 40 ºC
Humidity: <= 85 %
Pressure: 86.0 kPa ~ 106.0kPa
Transport and Storage environment :
Temperature: -20 ~ 55 ºC
Humidity: <= 93 %
Pressure: 86.0 kPa ~ 106.0kPa
Power Requirements
AC: 100 ~ 240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion battery
2h operating after full charge
5min operating after low battery alarm
Dimension and Weight
Equipment:
210mm × 85mm ×180mm; 1.40 kg
Package:
250mm ×175mm × 240mm; 3.4 kg
Date Storage
Trend diagram/table: 720h
NIBP review: 10000 events
Wave review: 12h
Alarm review: 200 alarm events
Support drug concentration titration analysis
ECG
5 Leads: RA, LA, LL, RL, V
Lead mode: ,, , AVR, AVL, AVF, V
Gain: × 1.25mm/mV,2.5mm/mV,
5.0mm/mV, 10mm/mV,
20mm/mV (error ≤ 5%)
Sweep speed: 6.25mm/s,12.5mm/s,25mm/s,
50mm/s (error ≤ ± 10%)
Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Sensitivity: >200 μ V P-P
CMRR: ≥ 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential: ±300mV
Polarization Voltage: ≥ ± 500mV
Input Impedance: ≥ 5 M
Calibration Voltage: 1mV ± 5%
ST Segment
ST Segment Range: -2.0mV ~ +2.0mV
Accuracy: 0.02mV
NIBP
Method: Oscillometry
Measure mode: Manual, Auto, STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40 ~ 240bpm
Measure & alarm range: Adult
SYS 40 ~ 280mmHg
DIA 10 ~ 220mmHg
MEAN 20 ~ 240mmHg
Pediatric
SYS 40 ~ 220mmHg
DIA 10 ~ 160mmHg
MEAN 20 ~ 170mmHg
Neonatal
SYS 40 ~ 135mmHg
DIA 10 ~ 100mmHg
MEAN 20 ~ 110mmHg
Static pressure measurement
Range: 0 ~ 300mmHg
Accuracy: ± 3mmHg
Resolution: 1mmHg Accuracy:
Max. Mean Error: ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
Adult 300mmHg
Pediatric 240mmHg
Neonatal 150mmHg
SpO2
Measurement range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100% ± 2%
40% ~ 69% ± 3%
Pulse Rate
Measure/alarm range: 20 ~ 300bpm
Resolution: 1bpm
Accuracy: ± 3bpm
RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3 ~ 3 Ω
Base Impedance range: 200 Ω ~ 4000 Ω
Bandwidth: 0.3 ~ 2.5Hz
Gain: × 0.25, × 0.5, × 1, × 2, × 4
Resp rate:
Measurement Range
Adult 0 ~ 120BrPM
Neonatal/Pediatric 0 ~ 150BrPM
Resolution: 1BrPM
Accuracy: 7 ~ 150BrPM ( ± 2BrPM)
0 ~ 6BrPM (unspecified)
Apnea Alarm: 10 ~ 40s
TEMP
Channel 2
Measure & alarm range: 0 ~ 50 ºC
Resolution: 0.1 ºC
Accuracy (no sensor): ±0.1 ºC (0~50 ºC)
Standard accessories
NIBP cuff & tube
ECG cable & electrodes
SpO2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator's manual
Optional accessories
Touch screen
Trolley bracket
Hanging bracket
Monitor recorder
Vehicle-mounted power supply
MOQ | 1 pcs |
Warrenty | 1 year |